Maxtron DEO SAE 10W-30

Make
CATERPILLAR
Model
CB7 (S/N NLJ00001 - Up) (Vibratory Compactors - Double Drum)
Engine
DT
Year
2017-
Application
Recommendation
Capacity (gal)
Engine (DT) (Cat C3.4B)
Premium
Maxtron DEO SAE 10W-30 (a, b, c)
2.33
Mainline
Superlube TMS SAE 10W-30
Transmission
From Hydraulics
Coolant
Refer to Technical (d)
5.02 - 5.81
Hydraulics
Power Transmission Fluid SAE 10W (e, f, g)
9.51
Grease Points
HD Moly Xtreme NLGI 2 (h)
Eccentric Weight Housing (Oscillation Drum - each)
Refer to Technical (i, j)
1.32
Eccentric Weight Housing (Solid Drum - non Versa-Vibe, each)
Refer to Technical (k, l)
3.12
Eccentric Weight Housing (Solid Drum - Versa Vibe, each)
Refer to Technical (m, n)
2.59
Eccentric Weight Housing (Split Drum - each)
Refer to Technical (o, p)
1.93
Final Drive Reduction Hubs (Drum - each)
Maxtron GL 75W-140 (q)
0.238

General Notes

There are no notes to display for this model

Lubricant / Capacity Notes

a.
0°F to 122°F
b.
Alternative recommendations, 0°F to 122°F: Maxtron DEO SAE 10W-30 / Superlube TMS SAE 10W-30
c.
Alternative recommendations, 14°F to 122°F: Maxtron DEO SAE 15W-40 / Superlube TMS SAE 15W-40
d.
Mix ratio, 50% >-37°C
e.
-4°F to 104°F
f.
Alternative recommendations, -4°F to 104°F: Refer to Technical
g.
Alternative recommendations, 5°F to 122°F: Maxtron DEO SAE 15W-40 / Superlube TMS SAE 15W-40
h.
Alternative recommendations: Maxtron EP NLGI 2
i.
-4°F to 122°F
j.
Alternative recommendations, -4°F to 122°F: Refer to Technical
k.
-4°F to 122°F
l.
Alternative recommendations, -4°F to 122°F: Refer to Technical
m.
-4°F to 122°F
n.
Alternative recommendations, -4°F to 122°F: Refer to Technical
o.
-4°F to 122°F
p.
Alternative recommendations, -4°F to 122°F: Refer to Technical
q.
-31°F to 113°F

Oil Change Intervals

Engine (DT) (Cat C3.4B)
Months Max
6
Hours Max
500
Coolant
Months Min
36
Months Max
72
Hours Min
6000
Hours Max
12000
Hydraulics
Months Max
12
Hours Max
2000
Eccentric Weight Housing (Oscillation Drum - each)
Months Max
36
Hours Max
2000
Eccentric Weight Housing (Solid Drum - non Versa-Vibe, each)
Months Max
36
Hours Max
3000
Eccentric Weight Housing (Solid Drum - Versa Vibe, each)
Months Max
36
Hours Max
3000
Eccentric Weight Housing (Split Drum - each)
Months Max
36
Hours Max
3000
Final Drive Reduction Hubs (Drum - each)
Hours Max
500