Your selected equipment
- Make
- WAGNER
- Model
- ST-3.5 (Detroit Diesel 4-71TI) (Tunnel Loaders)
- Engine
- DT
Application |
Recommendation |
Capacity (gal) |
Data Sheet |
Sales Sheet |
|
---|---|---|---|---|---|
Engine (DT) |
Ultra Premium
|
Superlube 518 Diesel Engine Oil SAE 40
|
4.36 / 5.94
|
||
Mainline |
Superlube TMS SAE 15W-40
|
||||
Transmission |
Ultra Premium
|
Maxtron THF +
(a)
|
3.49 / 4.99
|
||
Premium |
Qwiklift HTB
|
||||
Coolant |
Refer to Technical
(b)
|
|
|||
Hydraulics |
Refer to Technical
|
44.9
(c)
|
|||
Grease Points |
Maxtron EP NLGI 2
|
|
|||
Converter |
Ultra Premium
|
Maxtron THF +
|
1.51
|
||
Premium |
Qwiklift HTB
|
||||
Front & Rear Axles (each) |
Ultra Premium
|
Maxtron GL 75W-140
|
4.23 / 4.76
|
||
Premium |
MP Gear Lube SAE 85W-140
|
||||
Planetaries (each) |
Ultra Premium
|
Maxtron GL 75W-140
|
1.64 / 0.977
|
||
Premium |
MP Gear Lube SAE 85W-140
|
Engine (DT)
Recommendation:
Ultra Premium
Superlube 518 Diesel Engine Oil SAE 40
Mainline
Superlube TMS SAE 15W-40
Capacity 4.36 / 5.94(gal)
Transmission
Capacity 3.49 / 4.99(gal)
Coolant
Recommendation:
Ultra Premium
Refer to Technical
Hydraulics
Recommendation:
Ultra Premium
Refer to Technical
Capacity 44.9(gal)
(c)
Converter
Capacity 1.51(gal)
Front & Rear Axles (each)
Capacity 4.23 / 4.76(gal)
General Notes
There are no notes to display for this model
Lubricant / Capacity Notes
- a.
- Alternative recommendations, Transmission, Clark: Refer to Technical
- b.
- Cooling System: Use Ethylene Glycol or Propylene Glycol antifreeze at a ratio of 30%, or one part antifreeze to two parts water. For Detroit Diesel engines 50% Ethylene Glycol antifreeze is recommended but Propylene Glycol is only suitable for the 40, 50 and 60 series, at 30%. Caterpillar recommend that Propylene Glycol should only be used at a ratio of 50%
- c.
- Hydraulic reservoir capacity
Oil Change Intervals
Engine (DT)
- Hours Max
- 250
Transmission
- Hours Max
- 500
Coolant
- Months Max
- 24
Hydraulics
- Hours Max
- 1000
Converter
- Hours Max
- 1000
Front & Rear Axles (each)
- Hours Max
- 1000
Planetaries (each)
- Hours Max
- 1000