Close Print

Maxtron DEO SAE 15W-40

Make
CATERPILLAR
Model
304.5 (Mini Hydraulic Excavators)
Engine
D / DT
Application
Recommendation
Capacity (gal)
Engine (D / DT)
Premium
Maxtron DEO SAE 15W-40 (a)
2.22
Mainline
Superlube TMS SAE 15W-40
Transmission
From Hydraulics
Final Drives (each)
Ultra Premium
Maxtron GL 75W-140 (b, c, d, e)
0.291
Premium
MP Gear Lube SAE 85W-140
Coolant
Refer to Technical
1.4 - 1.66
Hydraulics (Tank/System)
Indol EH ISO 46 (f, g, h, i, j)
14.8 / 22.5
Greases: Molybdenum
Maxtron EP NLGI 2
Greases: Multipurpose
Ultra Premium
Maxtron FS NLGI 2
Premium
Maxtron EP NLGI 2
Mainline
Blue Gard 500+ NLGI 2
Greases: Special Purpose (high temp. antifriction bearings)
Poly-Xtreme NLGI 2
Rollers & Idlers
Ultra Premium
Superlube 518 Diesel Engine Oil SAE 30
Mainline
Superlube TMS SAE 10W-30

General Notes

There are no notes to display for this model

Lubricant / Capacity Notes

a.
Caterpillar list API CH-4 and API CI-4 as preferred oils and API CG-4 as an acceptable alternative. These oils must meet Caterpillar's ECF-1 specification to avoid reduced engine life. API CF-4 should not be used in Caterpillar diesel engines
b.
Alternative recommendations, -22°F to 104°F: Maxtron Enviro-EDGE GL 75W-90
c.
Alternative recommendations, -4°F to 104°F: Maxtron Enviro-EDGE GL 75W-90 / MP Gear Lube SAE 80W-90
d.
Alternative recommendations, 14°F to 122°F: Maxtron GL 75W-140 / MP Gear Lube SAE 85W-140
e.
Alternative recommendations, 32°F to 104°F: Maxtron Enviro-EDGE GL 75W-90 / MP Gear Lube SAE 80W-90
f.
Caterpillar list API CG-4, API CF and CAT TO-4 as alternative specifications. These oils must have a minimum zinc content of 900 ppm
g.
23°F to 113°F
h.
Alternative recommendations, -4°F to 104°F: Refer to Technical; Power Transmission Fluid SAE 10W; Maxtron DEO SAE 10W-30 / Superlube TMS SAE 10W-30
i.
Alternative recommendations, 5°F to 122°F: Maxtron Power Transmission Fluid MV
j.
Alternative recommendations, 32°F to 122°F: Refer to Technical

Oil Change Intervals

Engine (D / DT)
Hours Max
250
Final Drives (each)
Months Max
12
Hours Max
2000
Coolant
Months Max
24
Hours Max
2000
Hydraulics (Tank/System)
Months Max
18
Hours Max
3000